HomeWaterGiene
Water applications · 20 seconds

WaterGiene

ATP Water Test

The WaterGiene is a simple 20-second test with enhanced sensitivity measuring total ATP in water and on wet surfaces. Suitable for CIP systems, purified water systems, cooling water, clean rooms, surgical instruments, fermentation/tablet press equipment and rinse water. Can swirl in a water sample or swab a surface.

Enhanced ATP sensitivity to microbes using vacuum filtration for fast remediation. Recyclable components, patented thread design, pre-moistened swab with biofilm-breaking tip and metal-detectable foil seal. Compatible with novaLUM II-X via dedicated H2OG channel.

Performing the WaterGiene ATP water test with the novaLUM® II-X

1
Swab
2
Twist and Shake
3
Insert Swab
4
Read with novaLUM II-X
From setup to result

Step-by-step test procedure — WaterGiene

Follow the steps for preparation, sampling, activation and measurement.

PrepareSampleActivateMeasure11 steps
  1. Prepare

    Open PLANS

    WaterGiene — step 1: Open PLANS

    Tap PLANS on the novaLUM II-X home screen.

  2. Prepare

    Choose sampling plans

    WaterGiene — step 2: Choose sampling plans

    Select PLANS again to open the list of saved sampling plans.

  3. Prepare

    Start the correct plan

    WaterGiene — step 3: Start the correct plan

    Select RUN next to the sampling plan for this test.

  4. Prepare

    Select the sampling location

    WaterGiene — step 4: Select the sampling location

    Use the left/right arrows or list view to select the correct location. Check the WG screen code. Enter operator details if required.

  5. At the sampling location

    Withdraw the swab at the sampling location

    WaterGiene — step 5: Withdraw the swab at the sampling location

    Move the test to the sampling location with the holder closed. Only there, immediately before sampling, gently withdraw the swab with a slight twisting motion. Do not touch the swab tip.

  6. Sample

    Take the water sample

    WaterGiene — step 6: Take the water sample

    Dip the WaterGiene swab into the liquid for 5 seconds until fully saturated.

  7. Activate

    Reinsert and activate

    WaterGiene — step 7: Reinsert and activate

    Reinsert the swab and twist the handle fully down. Gently shake sideways 3 times.

  8. Activate

    Shake the test again

    WaterGiene — step 8: Shake the test again

    Unscrew the handle completely. Hold the handle and shake the WaterGiene test 3 times so liquid is forced into the microtube. Twist the handle fully down again.

  9. Activate

    Remove the black microcap

    WaterGiene — step 9: Remove the black microcap

    Remove the black microcap only after activation, immediately before inserting the test into the novaLUM II-X. Check that the white tablet has broken apart.

  10. Measure & assess

    Insert the test and measure

    WaterGiene — step 10: Insert the test and measure

    Insert the WaterGiene fully into the measurement chamber. Hold the novaLUM II-X upright and press the Run Test icon to start the measurement.

  11. Measure & assessExample screen

    Read the result

    WaterGiene — step 11: Read the result

    This manufacturer procedure specifies 20 seconds. Assess PASS/FAIL against your configured limit. The screen shown displays an example result.

Technical specifications of the WaterGiene ATP water test

ApplicationWater and wet surfaces
Test time20 seconds
Instrument channelH2OG (20 sec.)
StorageRefrigerated (0–7°C)
Room temp. stableMinimum 1 week
pH range4–9
Compatible instrumentnovaLUM II-X, novaLUM II, FireFly2

Advantages of ATP measurement in water compared to microbiological culture

Results in just 20 seconds
Ability to swirl in water sample or swab a surface
Enhanced ATP sensitivity to microbes using vacuum filtration
Detects ATP in process water, rinse water and wet surfaces
Dedicated H2OG channel for enhanced sensitivity
Recyclable components for reduced waste
Metal detectable foil seal
Patented thread design for consistent results

Sensitivity Data

Bacteria studied: E. coli, Pseudomonas, Citrobacter, and Enterobacter. Divide by 25 to convert to approximate surface concentration (cfu/100 cm²).

Bacterial ConcentrationMean RLU% Positive
210.000 cfu/mL1.847.967 RLU100%
21.000 cfu/mL73.581 RLU100%
2.100 cfu/mL0 RLU0%
150 cfu/mL0 RLU0%

Applications: ATP measurement in process water, drinking water and cooling water

Clean In Place (CIP) Systems
Cooling Water
Animal Laboratory Housing
Fermentation/Tablet Press Equipment
Purified Water Systems
Clean Rooms
In Line Filters
Rinse Water
Sterile/Non-Sterile Vial & Syringe Filling
Storage Tanks/Silos
Tap and Supply Water
Surgical Instruments

WaterGiene order codes and packaging options

POCK-H20P-25KWaterGiene — 25 units
POCK-H20P-50KWaterGiene — 50 units
POCK-H20P-100KWaterGiene — 100 units

See Operator's Manual for additional kits and order codes.

Ready to optimise your hygiene?

Request a free demo or receive a custom quote for your production environment.