ATP Hygiene
Monitoring
Systems
Real-time verification of cleaning processes in the food industry. Detect biological residues in 5 seconds — direct pass or fail.

ATP swabs and bioluminometers for HACCP cleaning verification
From ATP luminometer to specialised swabs for water, surfaces and allergens — everything for a reliable HACCP hygiene programme.

novaLUM II-X
Handheld ATP luminometer with touch screen, 9-hour battery life and WiFi/USB sync. Compatible with PocketSwab Plus, AllerGiene, WaterGiene and FieldSwab. novaLINK 6 software with LIMS integration, auto-email reports and SQF/BRC/FSC22000 audit documentation.

PocketSwab Plus
Results in 5 seconds. Room temperature stable (12-month shelf life), recyclable components and metal-detectable foil seal. Suitable for food, beverage, pharmaceutical, healthcare and 16 other industries.

FieldSwab
Results in 30 seconds. Specifically designed for outdoor and field applications such as harvesting equipment, transport containers and irrigation systems. Stable at 2–25°C (12 months), integrates into Good Agricultural Practices (GAP) programs.

WaterGiene
Results in 20 seconds. Enhanced sensitivity via dedicated H2OG channel. Can swirl in water sample or swab a surface. Suitable for CIP systems, purified water systems, cooling water, clean rooms and surgical instruments.

AllerGiene
Results in under 45 seconds. Dedicated AG channel for enhanced sensitivity. Detects 9 major allergens (shellfish, egg, fish, peanut, milk, sesame, soy, tree nuts, wheat). Suitable for cleaning validation and HACCP audit documentation.

RODAC Contact Plates
Ready-to-use RODAC contact plates for direct surface sampling. Three variants: VRBG (Enterobacteriaceae), TSA (total viable count) and SAB (yeasts & moulds). Convex agar surface for optimal contact, sterile and ready to use.

PUR-Blue™
Polyurethane microbiological swab with unique blue color for visual contamination verification. Patented PUR-foam tip absorbs 10x more liquid than cotton. Ideal for surface sampling, water testing and environmental monitoring.

EZ Reach™
Sponge sampler with innovative twist-off handle for reaching difficult-to-access areas. Sterile polyurethane sponge with neutralization buffer. Suitable for HACCP sampling of equipment, pipes and surfaces.

SampleRight™
Polyurethane sponge sampler for large surfaces. Sterile sponge in neutralization buffer, ready to use. Validated for Listeria, Salmonella and other pathogens. Widely applicable in food industry, pharma and medical environments.

Carcass & Poultry
Specialized boot swabs and carcass wipes for poultry and slaughterhouse hygiene. Chicken Boot Swabs for environmental sampling, Carcass Wipes for direct carcass control. Compliant with EU regulations for Salmonella monitoring.

Halal Select™
Sponge and swab samplers from World Bioproducts for microbiological environmental monitoring in halal-sensitive processes. Seven variants, dry or with HiCap™ Neutralizing Broth; check certificate scope per SKU.
How ATP testing works with a bioluminometer
The novaLUM II-X measurement takes 5 seconds. ATP (adenosine triphosphate) is present in all living cells — bacteria, food residues and other biological contaminants. The bioluminometer measures the amount of light released when ATP reacts with luciferin and luciferase. The more light (RLU), the more contamination.
Wipe the surface with the PocketSwab Plus. The swab picks up biological residues.
Insert the swab into the novaLUM II-X luminometer. Result in 5 seconds.
The system compares the RLU result against your set limit and immediately gives a pass or fail.
On a fail result: re-clean and re-test. Data is automatically saved and synced to the cloud.
We are the official Charm Sciences distributor for Benelux, Germany and Scandinavia. The Charm novaLUM II-X bioluminometer uses PMT sensor technology — the same precision as laboratory equipment, now in a handheld ATP meter.
Charm Sciences technology used in over 60 countries. Validated against international standards.
Immediate pass/fail decision. No waiting, no lab analysis required.
From programme setup to training and ongoing technical support.
Automatic data logging, trend analysis and HACCP reporting via the novaLUM II-X.

novaLINK 6 software for trend analysis, reporting and HACCP documentation.
PMT sensor: light detection at the heart of measurement
The novaLUM II-X uses a Photomultiplier tube (PMT) for light detection. Consult the current product specification and validate limits in your own measurement environment before assessing measurement performance or process suitability.
ATP hygiene monitoring by industry
Every industry has its own requirements. Discover how the novaLUM II-X is used in your sector.
HACCP-compliant ATP testing for production lines, filling equipment and packaging machines.
Rapid cleaning verification for CIP systems, tanks and pipelines in dairy processing.
GMP-compliant ATP testing for cleanrooms, production facilities and validation studies.
Rapidly verify surface hygiene in operating theatres, ICUs and patient rooms.
Practical guide for QA & production
Selecting an ATP meter for your food facility
From critical sampling points and baseline data to practical limits and audit documentation.
Ready to start?
Request a free demo and see how ATP monitoring can improve your cleaning processes.